1. The system will now load the RocketRAID 2320 driver automatically.
2. When prompted “Where do you want to install the boot loader? ” in the “Boot
Loader Configuration” dialog, select “Master Boot Record (MBR)” to instruct the
system be to boot from the RocketRAID 2320.
Continue the installation as normal. You can refer to Red Hat Enterprise Linux
installation guide.
Note:
The system device mapping order is the same as the order shown in RocketRAID
2320 BIOS Setting Utility. If no other SCSI adapters are installed, the device marked
as “BOOT” or “HDD0”will identified as /dev/sda, “HDD1” as /dev/sdb, “HDD2” as
/dev/sdc, etc. When creating mount points, /boot must be mounted on /dev/sda.
3 - Installing the RocketRAID 2320 driver for an Existing System
Note: If a SCSI adapter is used to boot the system, make sure the RocketRAID 2320
controller BIOS loads/posts after the SCSI adapter’s BIOS. It may be necessary to
move the adapter(s) to another PCI slot.
Step 1 Obtain the Driver Module
Extract the module file from the file modules.cgz (from the driver disk) using the
following commands:
# mount /dev/fd0
# cd /tmp
# gzip -dc /mnt/floppy/modules.cgz | cpio -idumv
Driver modules for all supported kernel versions will be extracted. The driver module
for the active kernel is located under the directory that matches the kernel version (/
tmp/‘uname –r‘/rr2320.o).