Highpoint RocketRAID 2782 User Manual

Browse online or download User Manual for Power suppliers Highpoint RocketRAID 2782. HighPoint RocketRAID 2782 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Host Adapter User Guide

RocketRAID 2782 6Gb/s SAS/SATA Host Adapter User Guide Revision: 1.1 Date: May 2011 HighPoint Technologies, Inc.

Page 2

Hardware – Description and Installation 10 Hardware – Description and Installation 1-RocketRAID 2782 Host Adapter layout Port1-Port6 These represent

Page 3 - Contents

Hardware – Description and Installation 11 BEEP1-Speaker Alarm (speaker): the speaker emits and audible alarm in the case of Drive

Page 4 - Table of Contents

Hardware – Description and Installation 12 4. After installing the adapter, attach hard drives to the host adapter using the data cable. Each Mini-

Page 5

RocketRAID BIOS Utility 13 RocketRAID 2782 BIOS Utility The RocketRAID 2782 card will display its BIOS screen during the system's boot process.

Page 6 - HighPoint Technologies, Inc

RocketRAID BIOS Utility 14 BIOS Commands Create - this command is used to open the RAID Creation menu. Delete - this command will delete the sele

Page 7

RocketRAID BIOS Utility 15 Highlight the target disks using the arrow keys, then select using Enter. You can use the arrow keys to select from the

Page 8

RocketRAID BIOS Utility 16 1. Use the arrow keys to select the RAID level and press ENTER. 2. Use the arrow keys to highlight the Array Name op

Page 9 - 2 - Kit Contents

RocketRAID BIOS Utility 17 (the screen will display 1 ports at a time. A numeral will be displayed before each selected disk. This number designates

Page 10

RocketRAID BIOS Utility 18 the array, or N (no) key to cancel the creation process. 3 – Deleting Arrays Highlight the Delete command from the toolb

Page 11

RocketRAID BIOS Utility 19 4 - Add/Remove Spare Disks This Add/Remove Spare command is used to assign a hard disk to act as a Spare Disk. Spare Disk

Page 12 - 3 - Verifying Installation

2 Copyright Copyright © 2010 HighPoint Technologies, Inc. This document contains materials protected by International Copyright Laws. All rights re

Page 13 - Using the BIOS Utility

RocketRAID BIOS Utility 20 Select Boot Device – select which disk or array will act as the boot disk, if the motherboard BIOS instructs the card to

Page 14 - Initializing Disks:

HighPoint Software CD 21 HighPoint Software CD Each retail box includes a copy of the HighPoint Products Software CD. This CD can be used to gener

Page 15 - Creating Arrays:

HighPoint Software CD 22 Device Driver Installation – Windows Operating Systems We recommend visiting the RocketRAID product pages for the latest W

Page 16 - RocketRAID BIOS Utility

HighPoint Software CD 23 4. Select “I don’t have disc, show me other options”. 5. And then select “Browse my computer for driver software”.

Page 17

HighPoint Software CD 24 6. Browse to the location of the driver and click “Next”. 7. When asked: “Would you like to install this driver so

Page 18 - 3 – Deleting Arrays

HighPoint Software CD 25 8. Reboot the system when prompted. The RocketRAID 2782 host adapter will be ready for use after Windows reboots.

Page 19 - 5 - Settings

HighPoint Software CD 26 Installing the driver during a fresh Windows 7, 2008, Vista installation 1. Boot from the Windows Installation DVD. 2.

Page 20

HighPoint RAID Management Utilities (HRM) 27 HighPoint RAID Management Utilities (HRM) – Web GUI / CLI The HighPoint RAID Management Utility Suite,

Page 21 - HighPoint Software CD

HighPoint RAID Management Utilities (HRM) 28 1. Copy the Web RAID Management package from the RR2782 Software CD, to the desktop of the Linux operat

Page 22 - Installation

HighPoint RAID Management Utilities (HRM) 29 Debian/Ubuntu Linux Distributions – Installing the Web-based Management Utility For Debian/Ubuntu Linu

Page 23 - HighPoint Software CD

Table of Contents 3 Contents HIGHPOINT TECHNOLOGIES, INC. ... 6 HIGHPOINT ROCKETRAID 2782

Page 24

HighPoint RAID Management Utilities (HRM) 30 Linux Distributions – Command Line Interface (CLI) Command Line interface versions of the RocketRAID ma

Page 25

HighPoint RAID Management Utilities (HRM) 31 3) The HighPoint Web RAID Management Service install screen will display. Click Next to continue: 4)

Page 26

HighPoint RAID Management Utilities (HRM) 32 5) Specify the Destination folder and click Next: Confirm the install location, and click“ Next”: 6

Page 27

HighPoint RAID Management Utilities (HRM) 33 7) Specify the listening port. 7402 is the default setting, and recommended for most systems. 8) Ch

Page 28 - \HighPoint RAID

HighPoint RAID Management Utilities (HRM) 34 2 - Starting the Web GUI 1) Double-click the “HighPoint Web RAID Management” Icon on the Desktop to st

Page 29 - Uninstalling the Utility

HighPoint RAID Management Utilities (HRM) 35 3 - Web GUI – Icon Definitions The Rocket RAID Web GUI uses a variety of Icons to represent various sta

Page 30

HighPoint RAID Management Utilities (HRM) 36 9. :This shows the OCE/ORLM procedure has been stopped or paused. 10.:This icon is displayed above “Leg

Page 31

HighPoint RAID Management Utilities (HRM) 37 initialize and press “Submit”. The initialized disk can now be added to the array. Note: initializing d

Page 32

HighPoint RAID Management Utilities (HRM) 38 3) When creating a Redundant Array (RAID 1, 5, 10, 50), specify an initialization method. Select Backg

Page 33

HighPoint RAID Management Utilities (HRM) 39 Write Through – this option raises the level of data security. Data is written directly to disk when th

Page 34 - 2 - Starting the Web GUI

Table of Contents 4 Red Hat Enterprise/CentOS, Fedora Core, Open SuSE, SLES – Installing the Web-based Management utility ...

Page 35

HighPoint RAID Management Utilities (HRM) 40 5 - Web GUI - Configuring Spare Disks The term “Spare Disk” refers to a hard disk, or dedicated disk spa

Page 36

HighPoint RAID Management Utilities (HRM) 41 2) Click “OK” when the pop-up window is displayed. This will add the disk to the Spare Pool. 3) To r

Page 37

HighPoint RAID Management Utilities (HRM) 42 To Rebuild an array: 1) Click “Maintenance” towards the right of the target array. 2) Click “Add Disk

Page 38

HighPoint RAID Management Utilities (HRM) 43 4) The Web GUI will initiate the rebuild procedure, and display a progress bar. 7 - Web GUI - Maintain

Page 39

HighPoint RAID Management Utilities (HRM) 44 Scheduling Tasks: 1) Enter a name for the task in the “Task Name” field. 2) Specify the frequency of

Page 40

HighPoint RAID Management Utilities (HRM) 45 Click “SMART” besides each disk to see its SMART attribute status. SMART attributes vary based on t

Page 41

HighPoint RAID Management Utilities (HRM) 46 failure. To access these features, select Settings – System from the utility toolbar: Automatic RAID

Page 42

HighPoint RAID Management Utilities (HRM) 47 Enable Audible Alarm – enable or disable the card’s alarm. The alarm will sound if the disk or array sto

Page 43

HighPoint RAID Management Utilities (HRM) 48 9 - Web GUI - Event Notification The RocketRAID 2782 host adapters will record Administrator activit

Page 44

HighPoint RAID Management Utilities (HRM) 49 Configuring SMTP (E-mail) Notification The Web GUI provides an SMTP notification system – this feature

Page 45

Table of Contents 5 Troubleshooting Checklist ... 58 THANK YOU ...

Page 46 - Automatic RAID Rebuilding

HighPoint RAID Management Utilities (HRM) 50 before the target E-mail address and click the “Delete” button. 10 - Web GUI - Advanced RAID Functions

Page 47

HighPoint RAID Management Utilities (HRM) 51 1. The VSS option is provided towards the bottom of the Create Array menu. In this example a 4-disk RAI

Page 48

HighPoint RAID Management Utilities (HRM) 52 5. Double-click “Administrative Tools”. 6. Double-Click “Computer Management”. 7. Under “Storage”

Page 49

HighPoint RAID Management Utilities (HRM) 53 Disk Management 8. Click “Next” to continue

Page 50 - OCE/ORLM)

HighPoint RAID Management Utilities (HRM) 54 9. Click “Finish” to continue. 10. Right-click the “Unallocated” box and select “New Partition”. 11

Page 51

HighPoint RAID Management Utilities (HRM) 55 Online Capacity Expansion and RAID Level Migration (OCE/ORLM) OCE/ORLM allows you to add hard disks to

Page 52

HighPoint RAID Management Utilities (HRM) 56 3. The Web GUI will display the “Array Transforming” menu (similar to the create array menu). Array tra

Page 53 - 8. Click “Next” to continue

HighPoint RAID Management Utilities (HRM) 57 4. The Web GUI will notify you when the process starts. A progress bar will be displayed under the Stat

Page 54

Customer Support 58 Customer Support If you encounter any problems while utilizing the RocketRAID 2782 host adapter, or have any questions about thi

Page 55

Customer Support 59 Thank You Thank you for purchasing the RocketRAID 2782 SAS/SATA RAID Host adapter. We appreciate your support, and welcome any qu

Page 56

6 HighPoint Technologies, Inc. HighPoint Technologies, long recognized as a leader in mass storage technologies specializes in the design and manufa

Page 57

Customer Support 60 FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits fo

Page 58 - Customer Support

HighPoint RocketRAID 2700 Series 7 HighPoint RocketRAID 2782 – PCI-Express 2.0×16 The RocketRAID 2782 host adapter is a high-performance SAS RAI

Page 59 - Thank You

HighPoint RocketRAID 2700 Series 8 1 - Features and Specifications Host Adapter Architecture • PCI-Express x16 (Gen2) • Support up 32 SAS/SATA dr

Page 60

HighPoint RocketRAID 2700 Series 9 HighPoint RAID Management (HRM) • Hot key (ctrl-h) boot-up RAID manager via BIOS • Web browser-base RAID mana

Comments to this Manuals